Military Grade Hybrid Microcircuit

Screening Specifications (Tcase = 85°C)

Test
Procedure
MIL-STD-883
Method
MIL-STD-883
Condition
Detail
Requirements
MDI
Screening
Internal Visual 2017 Same
Temperature Cycling 1010 B -55°C to +125°C
10 Cycles
Same
Mechanical Shock or Constant Acceleration 2002 and
2001
B1 Y1 Only
A1 Y1 Only
1500Gs
5000 Gs
Constant Acceleration
500 Gs standard1
Electrical Test Functional Test Same
Burn-in (85°C) 1015 85°C Tcase
160 hrs2 (Max. applied voltage and current)
Same
(Nominal input voltage and 100% rated load)
Final Electrical Test MDI ATP
PDA = 10%
Same
-55°C, 25°C, 85°C testing with data2
Fine Leak 1014 A1 or A2 Dependent on Vacant Interior Cavity of Hybrid Same
Gross Leak 1014 C1 Same
External Visual 2009 Same

Note 1 — Higher acceleration test levels available: Consult factory.
Note 2 — Industrial Grade Converters: 24 hours burn-in, 25°C test data only.
 
 

Page Revised 06/13/2006